The Dometic CCC 2 thermostat can store two operating programs. Each program can be set on individual zones with different mode and time settings for each zone.

For each event the user can program the operating mode, fan speed, temperature set-point, and the time of day for the event.

  1. Select the zone to be programmed.

  2. Select program “1” by pressing the PROGRAM button. “PROG 1” icon will blink on the LCD display.

  3. Press the CLOCK button to set the time of day for program to start.

  4. Press the MODE button to select the mode of operation.

  5. Press the FAN button to select the fan speed.

  6. Press the PROGRAM button to save the “PROG 1” settings. LCD will now display “PROG 2”.

To set program “2”, repeat steps (3) through (5).

7 . Press the PROGRAM button again to save program(s) in memory. Depending on the time of day, program “1” or “2” will begin immediately. For instance, if program “1” is set to begin at 10:00 AM and the time of day is 10:30 AM, program “1” will begin immediately. On the other hand, if program “1” is set to 10:00 AM and program “2” is set to begin at 6:00 PM and the time of day is 7:00 PM, program “2” will begin immediately.

When program “1” or “2” is operating, the “PROG 1” or “PROG 2” icon will be displayed in the LCD. The zone will continue to operate in the programmed setting until the program is manually canceled.

To cancel the program operation, press and hold the PROGRAM button for 3 seconds. The zone will be restored to normal operation.