2-way models are equipped with 2 fuses - one for the refrigerator control system and one for the AC heater.
3-way models are equipped with 3 fuses - two fuses in the power module and one in-line blade fuse.
💡NOTE: Some 2-way and 3-way models only include one 120V fuse on the control board as the 12VDC is onboard auto reset circuitry.
1
Turn off the refrigerator and unplug the power cord and disconnect the 12V wires.
2
Remove the power module cover .
3
Snap the fuse out of the fuse holder and fit the new fuse in to the fuse holder.
4
Put back the power module cover according to the instructions molded on the cover.
5
Reconnect the 12 VDC wires and plug in the
120 VAC power cord.
6
Turn ON the refrigerator.
The inline fuse for the power vent fans is connected to the 12V DC socket.
1
Disconnect 12V DC power.
2
Open the fuse holder.
3
Replace the fuse using a 3 A fuse.
4
Screw the holder back together.
5
Reconnect 12 VDC power.