Skip to Content
Support
Water Heaters - Combo Gas & ElectricMaintenance and Care Instructions

Water Heaters - Combo Gas & Electric

Maintenance and Care Instructions

⚠️WARNING FIRE OR EXPLOSION

  • Shut off gas supply at LP container before disconnecting a gas line.

  • Keep control compartment clean and free of gasoline, combustible material, and flammable liquids and vapors.


DO NOT USE Aftermarket heating elements, they can lack critical safety controls. To read more, see "Using After-Market Water Heating Element Devices" at the bottom.

GENERAL INFORMATION

LP and Water system must be turned on.

Have gas pressure tested periodically. Should be set at 11 inches of water column with three appliances running.

Drain water heater at regular intervals (at least one time during they year).

Drain water heater before storing RV for the winter or when the possibility of freezing exists.

Keep vent and combustion air grill clear of any obstructions.

Periodically, compare flame of main burners with the figure below:

Presence of soot indicates the need to adjust flue.

ELECTRONIC IGNITION MAINTENANCE

The water heater comes factory-equipped with a fused circuit board, which will protect the circuit board from wiring shorts. If the fuses should activate, the water heater will not operate. Before replacing the fuse, check for a short external to the board. Once the short is corrected, replace the 2 amp fuse with a mini ATO style fuse. Do not install a fuse larger than 3 amps.

If the fuse is good and the unit is inoperative, check for excessively high voltage to the unit (more than 14 volts).

Behöver du mer hjälp?

Ställ en annan frågaWater Heaters - Combo Gas & Electric
Välj en annan produkt
Sitemap
SupportSupport & ServiceFrequently asked questionsWarrantyFind a dealer
Privacy PolicyCookie NoticeTerms & ConditionsTerms of Use